Biosafety Cabinets include high-efficiency HEPA filters for the safe containment of hazardous particles. They have waterproof sockets, gas taps, and durable interiors for safe use. These units include alarms for abnormal airflow and filter replacement, ensuring user protection. They feature UV lamps for effective workspace sterilization, reducing microbial contamination. Our product ranges include Biosafety Cabinet Class II and Biosafety Cabinet Class III.

Biological Safety Cabinet TRBC-601

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
  • Noise : ≤65 dB(A)

Biological Safety Cabinet TRBC-602

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
  • Noise : ≤65 dB(A)

Biological Safety Cabinet TRBC-603

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
  • Noise : ≤65 dB(A)
Biological safety cabinet TRBC-604
  • The Average Wind Speed- Inner Side : 0.38 + -0.025m/s
  • The Average Wind Speed- Middle : 0.26 + -0.025 m/S
  • The Average Wind Speed-Inside : 0.35 + -0.025 m/s
  • Air Tightness : <=10 – 6 m/S 500 Pa leakage rate
Horizontal Laminar flow cabinet TRHL-603
  • Cleanliness Level : Class 100 @ ≥ 0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
  • Noise : ≤62dB (A)

Horizontal Laminar flow cabinet TRHL-604

  • Cleanliness Level : Class 100 @ ≥ 0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
  • Noise : ≤62dB (A)

Horizontal Laminar flow cabinet TRHL-601

  • Cleanliness Level : Class 100@≥0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
  • Noise : ≤62dB(A)

Horizontal Laminar flow cabinet TRHL-602

  • Cleanliness Level : Class 100@≥0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
  • Noise : ≤62dB(A)
Vertical Air Laminar Flow Cabinet TRVLC-601
  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-602
  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX

Vertical Air Laminar Flow Cabinet TRVLC-603

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX

Vertical Air Laminar Flow Cabinet TRVLC-604

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX

Vertical Air Laminar Flow Cabinet TRVLC-605

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-606
  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
Vertical and Horizontal Laminar Flow Cabinet TRVHC-602
  • The Average Wind Speed : 0.25 to 0.45m/s (Speed two-speed)
  • Noise : ≤62 dB
  • Power Supply : AC, 220 V/50Hz
  • MaximumPower Consumption : 800 W

Vertical and Horizontal Laminar Flow Cabinet TRVHC-601

  • The Average Wind Speed : 0.25 to 0.45m/s(Speed two-speed)
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • MaximumPower Consumption : 300W