A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type null

Filename: controllers/Website.php

Line Number: 123

Backtrace:

File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 123
Function: _error_handler

File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 36
Function: productdetail

File: /home/mednizco/public_html/centrifuges.com/index.php
Line: 321
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type null

Filename: controllers/Website.php

Line Number: 136

Backtrace:

File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 136
Function: _error_handler

File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 36
Function: productdetail

File: /home/mednizco/public_html/centrifuges.com/index.php
Line: 321
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type null

Filename: controllers/Website.php

Line Number: 137

Backtrace:

File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 137
Function: _error_handler

File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 36
Function: productdetail

File: /home/mednizco/public_html/centrifuges.com/index.php
Line: 321
Function: require_once

Spectrophotometer | Micro-spectrophotometer TRMS-602
Micro-spectrophotometer TRMS-602

Micro-spectrophotometer TRMS-602

Micro-spectrophotometer TRMS-602 is a new type of full-wavelength spectrophotometer used for the detection of samples. Constructed of stainless steel and quartz fiber with a built-in Bluetooth and WIFI modules, allowing for remote operation and wireless printing of results. It has a Wavelength Perusing Range of 190 to 850 nm, with an optical path of 1/0.5/0.05 mm automatic conversion.

Specifications

Optical Path 1/0.5/0.05 mm automatic conversion
Optical Range 190 to 1100 nm
Sample Volume 0.3 to 2.0 μl
Light Source Long-life Xenon lamp
Detector 3864 linear CCD array
Wavelength scanning Range 190 to 850 nm
Wavelength Accuracy ±1 nm
Wavelength Resolution 2 nm (FWHM Hg 546 nm)
Absorbance Accuracy 0.002 Abs
Absorbance Range 1% (0.76 absorbances at 350 nm)
Nucleic acid Range 0.002 to 300 Abs (equivalent to 10mm optical path)
Protein Range 0.4 to 15000 ng/μl (ds-DNA)
Detection Time 0.01 to 400 mg/ml (BSA)
Machine Size less than 3s
Weight 20×30×20 cm

Features

  • There is no need to warm up checking can begin at any time
  • Control and operation of the instrument, built-in Win10 system, constructed 7-inch high-definition showcase, full touch operation
  • 32GB of storage space is pre-installed
  • Two USB ports can be connected to a variety of devices
  • The platform is constructed out of stainless steel and quartz fiber
  • Built-in fiber to prevent fiber breakage caused by external force collision, resulting in chaotic measurement results
  • Built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
  • Users can save measuring device result data and design techniques straight in spreadsheet mode with a digital manual

Micro Spectrophotometer TRMS-604

  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Repeatability : <± 0.5 nm
catalog

Micro Spectrophotometer TRMS-605

  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Repeatability : <± 0.5 nm
catalog

Micro-Spectrophotometer TRMS-601

  • Light Path : 1mm
  • sample Volume : 1 to 2μL
  • Detection Range : 190 to 850 nm
  • Wavelength Range : 190 to 1100 nm
catalog

Micro-spectrophotometer TRMS-603

  • Wavelength scanning Range : 190 to 850 nm
  • Wavelength Accuracy : ±1 nm
  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
catalog